Space Air Conditioning Heat Reclaim Heat Pump Systems

Information from Space

Space Air Conditioning Heat Reclaim Heat Pump Systems
Heat Reclaim Heat Pump Systems

Space Air Conditioning Heat Reclaim Heat Pump Systems

Request Information on other Products

Contact Space

Request Quote or Pre-Tender information

Request CPD Seminar

Information from Space

 

Subscribe to Newsletter

Employers - Advertise Job or Position

Submit Candidates Curriculum Vitae

Building Design Home

Contact Building Design

Advertise your Company on Building Design

Terms of Use

Links

Information - Space

Air Cooled Chillers

VRF Air conditioning

Water Cooled Chillers

HRV Heat recovery

Fan Coil Units

 

Space Airconditioning plc

Daikin Hi-VRV

Rising energy and general building services running costs mean that end users expect far more than just cooling and heating from their air conditioning systems. A truly complete and acceptable system therefore, must be energy efficient, economic to run, easy to install, flexible, reliable
and user friendly.

Fresh air must also be supplied without increasing energy consumption and intelligent central management and control facilities have gained in importance, particularly for medium to large sized buildings.

The Daikin Hi-VRV system meets all these requirements. It is a combination of VRV air conditioning and HRV (Heat Recovery Ventilation) operated by Daikin’s building management systems such as I-Manager or I-Touch Controller for smaller applications.

Daikin Hi-VRV

Heat Reclaim Ventilation (HRV)

Efficient ventilation is a key element of the new Part F building regulations and Daikin’s heat recovery ventilation modules can be applied as stand alone units or incorporated within the air conditioning system.

Temperature and humidity are exchanged between the supply and exhaust air, recovering potential energy losses and reducing the air conditioning loads. The HRV modules feature a high efficiency VAM heat exchanger which enables the exchange of both sensible and latent heat energy and substationally increasing the energy transfer capacity. Four models with airflow rates from 350 to 2000 m³/h and optional DX Coil and
humidity control are available.
 

HRV Operation

HRV Operation

Air Flow Direction:
SA - Supply air to room
RA - Return air from room
EA - Exhaust air to outdoors
OA - Fresh air from outdoors

Heat Pump Systems

Daikin split, multi-split and VRV systems can be available for cooling only  applications, however heat pump versions are recommended, as these offer both efficient heating and cooling.

Air source heat pumps are classified as LZC (low to zero carbon) renewable technologies, as such they can help in meeting the requirements of Part L Building Regulations and the Uks carbon emission reduction targets.

VRV (Variable Refrigerant Volume Systems)

Daikin’s modular VRV heat pump and heat recovery systems provide the ultimate in space saving, energy efficient climate control systems, from the average size residence to the largest of buildings. VRV systems use inverter controlled scroll compressors resulting in the industry’s highest COPs (coefficient of performance) ratings.

The VRV range includes a water-cooled version (VRV-WII), which uses water as its heat source and VRVIII. The third generation VRV offers even more design flexibility through a number of technological advancements including increased capacity, longer pipe length capability, greater fan coil connectivity (up to 64) and enhanced energy efficiency. The system features automatic refrigerant charging with built-in leak detection and the refrigerant content has also been further reduced.

The mini VRV (VRVIII-S) bridges the gap between the multi-split and larger capacity VRV systems. Up to 9 fan coil units can be connected to the mini VRV system.

Split & Multi-Split Systems (Air to Air)

Ideal for small to medium sized properties of all types including offices, shops, restaurants, bars, schools or residential. Split and multi-split systems can operate up to five indoor units from a single outdoor cooling only or heat pump unit for year round comfort.

The new self cleaning round flow cassette indoor unit provides 360º air distribution discharge ensuring that there are no dead corners/temperature differences. The reduced air flow and temperature fluctuations results in fewer on/off cycles providing even further energy savings. The Self cleaning feature helps to eliminate ceiling staining that is common where ceiling units are installed.

23 different air flow patterns available.



Split & Multi-Split Systems (Air to Air)

Request information:
Daikin Air Water Cooled Chillers Fan Coils units

Request information:
Space air conditioning water chillers VRV heat reclaim ventilation

Technical information:
 Space Air Conditioning Air Conditioning Solutions Information

Daikin Chiller Technology

Heat Reclaim Ventilation System (HRV)

Space Airconditioning Plc
Willway Court
1 Opus Park
Moorfield Road
Guildford
Surrey
GU1 1SZ

Email this company

Tel: 01483 504 883
Fax: 01483 574 835

 

 

        Request further information:- please provide contact details: For UK and Europe only.* Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

 

 

      

* Please provide the project name and/or a short description of your requirements

      

 

Validation :
Please enter numbers shown



Request information: Space Air Conditioning Heat Reclaim Heat Pump Systems

Fully Featured HVAC Technical Services Advertisers

Actionair Requirements for Fire Dampers Future Developments Dampers

AET Hiross Flexible Space Underfloor Air Conditioning technical information

Airedale energy efficiency ratio eurovent EER classification

Andrews Water Heaters Condensing storage water heaters commercial heaters

Aquilar refrigerant gas detection F-gas regulations BS EN378 BREEAM

Armacell Insulation Selector Insulation Product Selector

Armstrong pressurisation selection boosting selection

Armstrong suction guides and Flo-Trex valves

Armstrong sewage pump selection drainage pump selection

Baxi SenerTec Combined heat power chp domestic chp micro chp

Belimo pressure independent characterised valve overview technical information

Britannia Kitchen ventilation canopies technical information

Britannia Kitchen ventilation recirculation units technical information

Carlyle Environmental Heat Pump Design Principles & Sound Levels

Carrier Complete Air Conditioning System Solution

Certuss steam generator installation steam generation technical information

Colman Moducel energy saving data centre cooling cooling distribution

Colt International water source heat pump guidance

Coolmation Rhoss chillers & hybrid heat pumps technical information

Daikin Modular Heat Reclaim Units Information

Danfoss VLT Drives Principles Advantages of Inverter Drives

Dimplex air source heat pumps ground source heat pumps

Dunham-Bush Fan Coil Unit Acoustics Fan Coil Room Noise Levels

Eaton-Williams Group humidifier guide humidifier specification humidifier technical information

EllisonAC Benefits of Packaged Plant Rooms Specification

EllisonAC Details of Packaged Plant Rooms Specification

Emcel Filters typical filtration unit specifications filter technical information

Ener-G Ground Source Heat Pump GSHP Energy Management

Food Industry Technical Ltd Variable Ventilation Control Gas Isolation Proving

Flakt Woods Energy Saving Technology Technical Information

Frenger Radiant Heating radiant heaters radiant ceiling panel

Frenger Multiservice Chilled Beams passive chilled beams active chilled beams

Fulton Boiler Works steam boiler installation steam boilers

Gilberts Floor Swirl Diffusers GFS Series

Halton Foodservice Kitchen Ventilation Canopies

Halton Indoor Fire Safety Solutions Fire Damper Management Smoke Dampers

Hitachi Split Systems & Variable Refrigerant Flow

JS Air Curtains why an air curtain aircurtain technical information

JS Humidifiers humidifier technical specifications

Mitsubishi Electric Case Studies 1

Mitsubishi Electric Case Studies 2

Monodraught natural daylight systems natural lighting

Munters Technical Information associated wtih Dehumidification Systems

PIPE2000 Pipework specifications Pipework technical information

Pipe2000 Floor Heating Floor Cooling technical information

Potterton Commercial Boilers Commercial condensing boilers commercial boiler manufacturer

Quidos Energy Management Consultants Air Conditioning Inspection and Certification

Raychem Underfloor Heating Product Selection

Raychem Trace Heating Product Selector

Rycroft sizing of Rycroft HT Breeze Sizing Rycroft

Sanyo gas heat pumps technical background

Siemens Building Technologies Guidance for Control Valves in HVAC Applications

Space Air Conditioning Air Conditioning Solutions Information

Space Air Conditioning Heat Reclaim Heat Pump Systems

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 1

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 2

Spirax Sarco steam pipe sizing condensate pipe sizing

Spirax Sarco steam tables steam data

Systemair Ltd Fan Engineering

Toshiba Split VRF Air Conditioning Systems Inverter Technology

Trend Control Sensor Installation Guide

Trend Psychrometric Chart

Trox Chilled Beams Technical Information Multi-service Chilled Beams

Trox Fan Coil Systems Technical Information VAV Fan

Uniflair close control AC data Uniflair chiller data

 

Building design directory Site Map
Page p1 p2 p3 p4 p5 p6 p7 p8 p9 p10 p11 p12 p13 p14 p15 p16 p17 p18 p19 p20 p21 p22 p23 p24

See also
Building Design News  |  Building Design Recruitment  |  Building Design Tenders

| Building Design Home | Request informationArchitectural CPD Seminars | HVAC CPD Seminars | Electrical CPD Seminars |
| Architectural Technical Pages Index | Electrical Technical Pages Index | Mechanical Technical Index | Discussion Help | News |

| F1 | F2 | F3 | F4 | F5 | A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products | Terms of Use |

Catalogue Requests
| Architectural Request Index | Catalogue Request Index 1  | Catalogue Request Index 2Catalogue Request Index 3 |
| Catalogue Request Index 4 | Catalogue Request Index 5 | Catalogue Request Index 6 |

Useful building design and construction links - | Links Directory |





Recruitment
| Architect Jobs | Electrical Engineer Jobs | Building Engineering Jobs | AutoCad Operator Jobs | Structural Engineer Jobs | Links |

Arundel Jones Associates LLP | Tel : 01622 745333 | e-mail |