Flakt Woods Energy Saving Technology Technical Information

Information from Flakt Woods

Flakt Woods Energy Saving Technology Technical Information
Energy Saving Technology Technical Information     

Flakt Woods Energy Saving Technology Technical Information

Request Information on other Products

Contact Flakt Woods

Request Quote or Pre-Tender information

Request CPD Seminar

Information from Flakt Woods

 

Subscribe to Newsletter

Employers - Advertise Job or Position

Submit Candidates Curriculum Vitae

Building Design Home

Contact Building Design

Advertise your Company on Building Design

Terms of Use

Links

Air Handling Units

Fans Axial / Centrifugal

Chilled Beams

Fan Coil Units

Grilles / Diffusers

Air Cooled Chillers

 

Fläkt Woods

Fläkt Woods Energy Saving Technology
Twin Wheel System

The Fläkt Woods Twin Wheels and Controls package is helping specifiers gain significant energy savings from air handling units providing fresh air to active chilled beams.

In any application with a high density of occupation within rooms, dew-point temperature control can now be achieved using the Fläkt Woods Wheels and Controls package to maintain room conditions. This has the dual effect of reducing the cooling load on the cooling coil and eliminating the requirement for reheat on the heater battery during the summer cycle, thus contributing to significant energy savings.

How it works

This system uses both a hygroscopic thermal wheel and a non-hygroscopic thermal wheel with a cooling coil in between. The non-hygroscopic wheel reheats the air from the cooling coil, eliminating the need for a reheater. At the same time, it cools the extract air. This cooled extract air goes onto the hygroscopic wheel and this provides enough cooling recovery to reduce a typical cooling load by half.

The package does not require a regeneration heater or adiabatic humidifiers.

Conclusions

Calculations show considerable energy savings over systems without any form of heat recovery. In practice, with today’s emphasis on energy recovery, most systems will include some method of heat recovery. Nevertheless, this system shows a marked efficiency improvement in the summer cycle and is better in the winter cycle than most systems with some form of heat recovery.

The Fläkt Woods Wheels and Controls package should also be considered for applications such as:

Chilled Beam Systems – the system dehumidifies the fresh air so that there is no risk of ‘rain’ in the zones served by three chilled beams. The system halves the fresh air cooling load and eliminates the need for a reheater.

Fan Coil Systems – the dehumidification of the fresh air to the fan coils will result in reduced moisture drop-out on the fan coils, reducing energy costs.

Displacement Ventilation Systems – full fresh air systems without humidifiers reduce the maintenance liability usually associated with humidifier systems, with energy savings.

Flakt Woods Energy Saving Technology Air Handling Unit
(Click on image for larger display)

Operation: The operation of the system is as follows : (refer to fig. 1)

Summer

E-G Outdoor air is initially cooled by the Fläkt Woods Wheels and Controls package.

G-H It is further cooled and dehumidified, using the cooling coil, to the required dew-point temperature.

H-C The supply air is then reheated to the required supply condition using the Fläkt Woods Wheels and Controls package, which extracts heat from the return air.

Winter

E-F Outdoor air heated by frost coil to 2ºC (only if required).

F-G Outdoor air heated and humidified by the Fläkt Woods Wheels and Controls package.

G-C Supply air further heated by the Fläkt Woods Wheels and Controls package.

C-J Heated to design condition by the heater battery.


Request information:
Flakt Woods Air Handling Equipment Fans AHUs Car Park Ventilation Grilles

Request information:
Flakt Woods Energy Recovery & Car Park Ventilation Fans AHUs Chilled Beams


Fläkt Woods Ltd

Fläkt Woods Ltd
Unit 6240 Bishops Court
Birmingham Business Park
Solihull Parkway
Birmingham
B37 7YB

Email this company

Tel : 0121 717 4680
Fax : 0121 717 4699

 

 

      Request further information:- please provide contact details: For UK and Europe only * Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

 

 

*Please provide the project name and/or a short description of your requirements

Validation :
Please enter numbers shown



Request information: Flakt Woods Energy Saving Technology Technical Information

Fully Featured HVAC Technical Services Advertisers

Actionair Requirements for Fire Dampers Future Developments Dampers

AET Hiross Flexible Space Underfloor Air Conditioning technical information

Airedale energy efficiency ratio eurovent EER classification

Andrews Water Heaters Condensing storage water heaters commercial heaters

Aquilar refrigerant gas detection F-gas regulations BS EN378 BREEAM

Armacell Insulation Selector Insulation Product Selector

Armstrong pressurisation selection boosting selection

Armstrong suction guides and Flo-Trex valves

Armstrong sewage pump selection drainage pump selection

Baxi SenerTec Combined heat power chp domestic chp micro chp

Belimo pressure independent characterised valve overview technical information

Britannia Kitchen ventilation canopies technical information

Britannia Kitchen ventilation recirculation units technical information

Carlyle Environmental Heat Pump Design Principles & Sound Levels

Carrier Complete Air Conditioning System Solution

Certuss steam generator installation steam generation technical information

Colman Moducel energy saving data centre cooling cooling distribution

Colt International water source heat pump guidance

Coolmation Rhoss chillers & hybrid heat pumps technical information

Daikin Modular Heat Reclaim Units Information

Danfoss VLT Drives Principles Advantages of Inverter Drives

Dimplex air source heat pumps ground source heat pumps

Dunham-Bush Fan Coil Unit Acoustics Fan Coil Room Noise Levels

Eaton-Williams Group humidifier guide humidifier specification humidifier technical information

EllisonAC Benefits of Packaged Plant Rooms Specification

EllisonAC Details of Packaged Plant Rooms Specification

Emcel Filters typical filtration unit specifications filter technical information

Ener-G Ground Source Heat Pump GSHP Energy Management

Food Industry Technical Ltd Variable Ventilation Control Gas Isolation Proving

Flakt Woods Energy Saving Technology Technical Information

Frenger Radiant Heating radiant heaters radiant ceiling panel

Frenger Multiservice Chilled Beams passive chilled beams active chilled beams

Fulton Boiler Works steam boiler installation steam boilers

Gilberts Floor Swirl Diffusers GFS Series

Halton Foodservice Kitchen Ventilation Canopies

Halton Indoor Fire Safety Solutions Fire Damper Management Smoke Dampers

Hitachi Split Systems & Variable Refrigerant Flow

JS Air Curtains why an air curtain aircurtain technical information

JS Humidifiers humidifier technical specifications

Mitsubishi Electric Case Studies 1

Mitsubishi Electric Case Studies 2

Monodraught natural daylight systems natural lighting

Munters Technical Information associated wtih Dehumidification Systems

PIPE2000 Pipework specifications Pipework technical information

Pipe2000 Floor Heating Floor Cooling technical information

Potterton Commercial Boilers Commercial condensing boilers commercial boiler manufacturer

Quidos Energy Management Consultants Air Conditioning Inspection and Certification

Raychem Underfloor Heating Product Selection

Raychem Trace Heating Product Selector

Rycroft sizing of Rycroft HT Breeze Sizing Rycroft

Sanyo gas heat pumps technical background

Siemens Building Technologies Guidance for Control Valves in HVAC Applications

Space Air Conditioning Air Conditioning Solutions Information

Space Air Conditioning Heat Reclaim Heat Pump Systems

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 1

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 2

Spirax Sarco steam pipe sizing condensate pipe sizing

Spirax Sarco steam tables steam data

Systemair Ltd Fan Engineering

Toshiba Split VRF Air Conditioning Systems Inverter Technology

Trend Control Sensor Installation Guide

Trend Psychrometric Chart

Trox Chilled Beams Technical Information Multi-service Chilled Beams

Trox Fan Coil Systems Technical Information VAV Fan

Uniflair close control AC data Uniflair chiller data

 

Building design directory Site Map
Page p1 p2 p3 p4 p5 p6 p7 p8 p9 p10 p11 p12 p13 p14 p15 p16 p17 p18 p19 p20 p21 p22 p23 p24

See also
Building Design News  |  Building Design Recruitment  |  Building Design Tenders

| Building Design Home | Request informationArchitectural CPD Seminars | HVAC CPD Seminars | Electrical CPD Seminars |
| Architectural Technical Pages Index | Electrical Technical Pages Index | Mechanical Technical Index | Discussion Help | News |

| F1 | F2 | F3 | F4 | F5 | A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products | Terms of Use |

Catalogue Requests
| Architectural Request Index | Catalogue Request Index 1  | Catalogue Request Index 2Catalogue Request Index 3 |
| Catalogue Request Index 4 | Catalogue Request Index 5 | Catalogue Request Index 6 |

Useful building design and construction links - | Links Directory |





Recruitment
| Architect Jobs | Electrical Engineer Jobs | Building Engineering Jobs | AutoCad Operator Jobs | Structural Engineer Jobs | Links |

Arundel Jones Associates LLP | Tel : 01622 745333 | e-mail |