Technical information associated with EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms

Information from EllisonAC

Technical information associated with EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms
EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms     

Technical information associated with EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms

Request Information on other Products

Contact EllisonAC

Request Quote or Pre-Tender information

Request CPD Seminar

Information from EllisonAC

 

Subscribe to Newsletter

Employers - Advertise Job or Position

Submit Candidates Curriculum Vitae

Building Design Home

Contact Building Design

Advertise your Company on Building Design

Terms of Use

Links

Information - EllisonAC

Information on other Products

Packaged Plant Rooms

Subscribe to Newsletter

Mobile Boiler Hire

Request CPD Seminar

 

EllisonAC

Benefits & Specification of Packaged Plant Rooms

Benefits of Using & Specifying EllisonAC

  • Design & fabrication is carried out totally in house

  • Consultancy & management time together with the associated costs are significantly reduced

  • Patented acoustic vented ridge for optimum temperature control

  • Patented method of fixing cladding panels giving a homogeneous finish

  • Concealed gutters& downspouts

  • Insulated floor preventing underfloor condensation & corrosion

  • Integrated electrical containment system

  • Removable cladding panels

  • Modular units extendable by 1172mm panels

  • Integral floor drainage

  • Acoustic & non-acoustic units

  • Delivery & installation normally carried out within 1 working day

  • The delivery will not have an effect on the critical path of the programme, as in-built plant does

  • The units can be fully tested, pre-commissioned & witnessed off site

  • Delivery time is normally 8-10 weeks from approval of drawings

Specification for EllisonAC

General

The container shall be manufactured by EllisonAC, provided with adequate means for lifting and positioning into final position utilising suitable cranage.

Construction

The container shall be a double skinned insulated one-piece unit constructed to be capable of accommodating the full operating load of the installed equipment/installations (both point loads and uniformly distributed loads).

Walls

External walls are to be constructed of steel panels, complete with adequate steel vertical supporting members at suitable centres. Heavy duty galvanised channel 41mm x 41mm x 2mm gap and 6mm return to be provided within each supporting member for pipework support and electrical containment systems as required.

External Finish

The steelwork frame to be generally painted with two coats air drying enamel to Colour Code BS.10A05 Goosewing Grey or equal.

Internal Finish

The steelwork frame to be as above. Silicone type sealant to be applied to panel joints where a weatherproof/air seal is required.

External/Internal Panels

Option A – Bonded Panels (also available as fire rated)
The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be 40mm thick zero ODP slab insulation.

Internally the panels will have bright white liner enamel affixed, encasing the whole panel.

Option B – Acoustic Panels (also available as fire rated)
The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be 80mm thick rockwool insulation.

Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation.

Option C – Bonded/Acoustic Panels (also available as fire rated)
The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be an 80mm thick combination panel of 40mm thick zero ODP slab insulation and 40mm thick rockwool insulation.

Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation.

All of the above cladding panels shall be affixed to the container from the outside thus allowing them to be removable should they be damaged or for plant replacement. Patent No. 2280206. All joints should have cover strips fitted, manufactured from the same materials as the external finish thus ensuring the unit has a homogeneous finish.

Roof

The roof shall be pitched from the central ridge, and shall be double skin, of steel construction, insulated to maintain minimum thermal transmittance. Roof finish to be same as walls (option A, B or C). Eaves to overhang walls. Guttering and downpipes shall be concealed type, manufactured from plastisol in the same colour as the unit.

Sub-Floor

Generally for container up to a gross weight of 20 tonnes the sub-floor and floor shall be as follows. All steel shall receive a coat of weldable primer. Shall be channel with the U-section of the channel facing all internal elevations. At 1M centres through the length of the container channel shall be fitted and run from side to side. All channels shall be fully weld prepped and receive 2 welds to all joints and butt joints. Running from end to end of the container shall be 2 sections of 100 x 100 angle which shall be weld prepped and fully welded.

Floor

On the floor shall be laid 4.5mm thick durbar plate and shall have no more than 4 joints throughout the total floor area. The durbar plate shall be welded to the sub-floor by stitch welding and there shall be a minimum of 20% of the steel contact area of the floor to the sub-base welded. All joints within the floor area shall be fully welded and prior to welding have been levelled from beneath to prevent ponding of water. A 200 x 4.5mm durbar kicker plate shall be welded to the completed floor to prevent damage to the container side panels. After the welding of the kicker plate the container shall be tested for leakage.

The completed floor shall receive 2-No. coats of epoxy non-slip semi matt floor paint to an approved colour. 1-No. coat shall be applied after completing all site works or commissioning. The sub-floor shall receive 2-No. coats of black bituminous paint applied by airless spray to ensure even coat to all steelwork.

Underfloor Insulation

To all the sub-floor area foil faced insulation board shall be affixed thus ensuring no underfloor condensation will form resulting in corrosion to the underfloor steelwork taking place.

Where entry point is requested through the floor, a 200mm high upstand detail can be provided, matching the general 200mm high skirting throughout the container.

Internal Drainage

Drainage will take place through the door thresholds out onto the roof area, or through an alternatively specified drain gully.

Doors

Outwards opening steel doors are to be provided as requested and hung on stainless steel security pattern hinges. Suitably designed internal door stays are also to be fitted and door clips to hold the doors back fully, if required. The minimum door opening is to be 1M wide x 2M high and is to be sized to facilitate removal of major plant/equipment items.

All doors to be constructed and insulated to the same thermal transmittance value as the container walls. A security lock is to be fitted.

Internal Plinths/Bases

Suitably designed pump plinths/bases can be provided where required, to comply with the requirements of equipment manufacturers.

Where bases are provided, they shall make all necessary provision to isolate vibration/noise transmission as required.


Request information above Ellison Packaged Plant Mobile Boiler Hire Containerised plantroom Solutions

Request information above Ellison Packaged Plant rooms Mobile Boiler Hire Containerised plantrooms Solutions

Technical information associated with:
EllisonAC - Benefits & Specification of Packaged Plant Rooms
EllisonAC - Details & Specification of Packaged Plant Rooms


Complete Containerised Plantroom Solutions

EllisonAC Limited
Woodgate Business Centre
White Lund Industrial Estate Morecambe
Lancashire
LA3 3PS

Email this company

Tel: +44 (0) 1524 847470
Fax: +44 (0) 1524 845992

 

        Request further information:- please provide contact details: For UK and Europe only.
        * Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

        Please provide the project name and/or a short description of your requirements
       *Your Requirements

Validation :
Please enter numbers shown



Request information above Technical information associated with EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms

Fully Featured HVAC Services Advertisers

2 Cool GEA Fan Coil Units AHUs Air Handling Gilberts Blackpool Grilles Diffusers VAV Terminals Louvres
A C Plastic Ind water storage tanks water storage tanks Guntner UK Dry Coolers Condensers Plate Heat
Actionair Fan Coil Units Control Systems Hot Shield Halton Foodservice VentMaster Kitchen Extract Canopies 
Advanced Air Fire Dampers Smoke Dampers Fan Coils Halton Multi Service Chilled Beams Iris Dampers Modular
AET Advanced Ergonomic Technologies Hiross underfloor  Hitachi Room Air Conditioning VRF Systems Air Chillers
Air and Water Centre Portable Air Conditioners Split wall Hitachi Heat Pumps Heat Recovery Ventilation Air Chillers
Air Diffusion Grilles Floor Grilles Diffusers Louvres Honeywell pressure regulating valves actuators invertor
Airedale chillers air handling units close control air IAC Limited Acoustic barriers acoustic insulation panels
Airedale Energy Efficiency Standards Seasonal Energy Ice Boys Portable air conditioning Portable air
Andrews Water Heaters Boilers Fan Flue Oil Fired JS Air Curtains JS Aircurtains entrance air curtains
Armacell Insulation Armaflex Arma Chek Ductwork JS Humidifiers steam humidifiers
Armstrong Holden Brooke Pullen pumps packaged Kingspan Insulation Ductwork Insulation Koolduct
Armstrong Holden Brooke Pullen pumps pressurisation Mitsubishi Electric VRF Air Conditioning Heat Pumps Air
Ashford Environmental Flushing Water Treatment Mitsubishi Electric VRF Air Conditioning Close Control Air
Baxi Technologies CHP combined heating and power Monodraught balanced flues natural ventilation sunpipe
Belimo actuators smoke damper fire actuators VAV Munters dehumidification desiccant de-humidification
Britannia kitchen ventilation canopies extract ventilated Potterton Commercial boilers packaged prefabricated 
Building Simulation Flow Science CFD computer Powrmatic Radiant Heating Water Heating Fan Convectors
Carlyle Environmental Water Source Heat Pumps Powrmatic Natural Ventilation Louvres Smoke Ventilation
Carrier Air Cooled Water Cooled Screw Chillers Quidos Energy Management Consultants Air Conditioning
Colt International Car Park Ventilation Smoke extract Raychem Trace Heating Tyco Thermal Controls Raychem
Colt International Water Source heat pumps UK Colt- Raychem Tyco Thermal Controls Electric Underfloor
Coolmation Rhoss Water cooled chillers air cooled Roberts-Gordon Combat space heaters linear radiant
Daikin VRF Air Conditioning Daikin Reclaim Air to Roberts-Gordon Combat direct indirect fired heating
Daikin Air Water Cooled Chillers Fan Coils units Rycroft water heating pressurisation Heatrae Industrial
Danfoss HVAC Inverter Drives VLT 2800 6000 Sanyo air conditioners gas heat pump GHP VRF
Dimplex Ground Source Heat Pumps Dimplex Sanyo air conditioners VRF air conditioning Gas Heat
Dunham Bush Air & Water Cooled Packaged Chillers Air Siemens Building Technologies Building Management
Dunham Bush AH-Us Radiant Heating Fan Coil Units Air Space air conditioning water chillers VRV heat reclaim
Eaton Williams Steam Humidifier Gas Fired Steam SPC S & P Coil Products Coils Heat Pipes Heaters 
Eaton Williams Colman Moducel grilles diffusers louvres Spirax Sarco Steam Services steam generators traps
Ellison Packaged Plant Mobile Boiler Hire Containerised Systemair Axial Centrifugal Fans In line Duct Plate
Ellison Packaged Plant rooms Mobile Boiler Hire The Banyard Group commissioning engineers HVAC M&E
Emcel Filters activated carbon filters particle filters safe Toshiba Split & VRF Air Conditioning Systems Inverter
EnerG GSHP Ground Source Heat Pumps Energy Recovery Trend Control Systems Building Management Systems
Pipe2000 Underfloor Heating PEX polyethylene pipes Trox Multi Service Chilled Beams Airconditioning Terminal
FIT Food Industry Technical energy saving kitchen  Trox IT Cooling CO2 Cooling Blade Server Cooling
Flakt Woods Air Handling Equipment Fans AHUs Underfloor heating UK - warm water underfloor heating
Flakt Woods Energy Recovery & Car Park Ventilation Uniflair close control air conditioning ac chillers heat
Frenger radiant panels electric radiant heating Van Spall Air Cooled Evaporative Cooling Adiabatic dry
Frenger chilled beams passive active chilled beams Viessmann gas condensing boilers heat pumps chp solar
Fulton Steam Boilers Fulton boilers steam thermal Weatherite Packaged Air Conditioning Air Handling units
GE Power Protection variable speed drives Manual Motor

 

| Building Design Home | Request informationArchitectural CPD Seminars | HVAC CPD Seminars | Electrical CPD Seminars |
| Architectural Technical Pages Index | Electrical Technical Pages Index | Mechanical Technical Index | Discussion Help | News |

| F1 | F2 | F3 | F4 | F5 | A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products | Terms of Use |

Useful building design and construction links - | Links Directory |





Recruitment -

| Architect Jobs | Electrical Engineer Jobs | Building Engineering Jobs | AutoCad Operator Jobs | Structural Engineer Jobs | Links |