EllisonACBenefits & Specification of Packaged Plant RoomsBenefits of Using & Specifying EllisonAC
Specification for EllisonACGeneralThe container shall be manufactured by EllisonAC, provided with adequate means for lifting and positioning into final position utilising suitable cranage. ConstructionThe container shall be a double skinned insulated one-piece unit constructed to be capable of accommodating the full operating load of the installed equipment/installations (both point loads and uniformly distributed loads). WallsExternal walls are to be constructed of steel panels, complete with adequate steel vertical supporting members at suitable centres. Heavy duty galvanised channel 41mm x 41mm x 2mm gap and 6mm return to be provided within each supporting member for pipework support and electrical containment systems as required. External FinishThe steelwork frame to be generally painted with two coats air drying enamel to Colour Code BS.10A05 Goosewing Grey or equal. Internal FinishThe steelwork frame to be as above. Silicone type sealant to be applied to panel joints where a weatherproof/air seal is required. External/Internal PanelsOption A – Bonded Panels (also available as fire
rated) Internally the panels will have bright white liner enamel affixed, encasing the whole panel. Option B – Acoustic Panels (also available as
fire rated) Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation. Option C – Bonded/Acoustic Panels (also available
as fire rated) Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation. All of the above cladding panels shall be affixed to the container from the outside thus allowing them to be removable should they be damaged or for plant replacement. Patent No. 2280206. All joints should have cover strips fitted, manufactured from the same materials as the external finish thus ensuring the unit has a homogeneous finish. RoofThe roof shall be pitched from the central ridge, and shall be double skin, of steel construction, insulated to maintain minimum thermal transmittance. Roof finish to be same as walls (option A, B or C). Eaves to overhang walls. Guttering and downpipes shall be concealed type, manufactured from plastisol in the same colour as the unit. Sub-FloorGenerally for container up to a gross weight of 20 tonnes the sub-floor and floor shall be as follows. All steel shall receive a coat of weldable primer. Shall be channel with the U-section of the channel facing all internal elevations. At 1M centres through the length of the container channel shall be fitted and run from side to side. All channels shall be fully weld prepped and receive 2 welds to all joints and butt joints. Running from end to end of the container shall be 2 sections of 100 x 100 angle which shall be weld prepped and fully welded. FloorOn the floor shall be laid 4.5mm thick durbar plate and shall have no more than 4 joints throughout the total floor area. The durbar plate shall be welded to the sub-floor by stitch welding and there shall be a minimum of 20% of the steel contact area of the floor to the sub-base welded. All joints within the floor area shall be fully welded and prior to welding have been levelled from beneath to prevent ponding of water. A 200 x 4.5mm durbar kicker plate shall be welded to the completed floor to prevent damage to the container side panels. After the welding of the kicker plate the container shall be tested for leakage. The completed floor shall receive 2-No. coats of epoxy non-slip semi matt floor paint to an approved colour. 1-No. coat shall be applied after completing all site works or commissioning. The sub-floor shall receive 2-No. coats of black bituminous paint applied by airless spray to ensure even coat to all steelwork. Underfloor InsulationTo all the sub-floor area foil faced insulation board shall be affixed thus ensuring no underfloor condensation will form resulting in corrosion to the underfloor steelwork taking place. Where entry point is requested through the floor, a 200mm high upstand detail can be provided, matching the general 200mm high skirting throughout the container. Internal DrainageDrainage will take place through the door thresholds out onto the roof area, or through an alternatively specified drain gully. DoorsOutwards opening steel doors are to be provided as requested and hung on stainless steel security pattern hinges. Suitably designed internal door stays are also to be fitted and door clips to hold the doors back fully, if required. The minimum door opening is to be 1M wide x 2M high and is to be sized to facilitate removal of major plant/equipment items. All doors to be constructed and insulated to the same thermal transmittance value as the container walls. A security lock is to be fitted. Internal Plinths/BasesSuitably designed pump plinths/bases can be provided where required, to comply with the requirements of equipment manufacturers. Where bases are provided, they shall make all
necessary provision to isolate vibration/noise transmission as
required.
|
EllisonAC Limited
Email this company
|
||||||||||||||||||||||||||||||||||||||||
| Building Design
Home | Request information | Architectural
CPD Seminars | HVAC CPD
Seminars | Electrical CPD
Seminars |
| Architectural
Technical Pages Index |
Electrical Technical
Pages Index |
Mechanical Technical Index | Discussion
Help | News |
| F1 |
F2 |
F3 |
F4 |
F5 |
A1 |
A2 | A3 |
A4 |
A5 | Architectural Products |
HVAC Products |
Electrical Products | Terms of Use |
Useful building design and construction links -
| Links Directory |
Recruitment -
| Architect Jobs |
Electrical Engineer Jobs |
Building Engineering Jobs |
AutoCad Operator Jobs |
Structural Engineer Jobs |
Links |