Benefits & Specification of Packaged Plant Rooms

Benefits of Using & Specifying EllisonAC Packaged Plant Rooms

  • Design & fabrication is carried out totally in house
  • Consultancy & management time together with the associated costs are significantly reduced
  • Patented acoustic vented ridge for optimum temperature control
  • Patented method of fixing cladding panels giving a homogenous finish
  • Concealed gutters& downspouts
  • Insulated floor preventing underfloor condensation & corrosion
  • Integrated electrical containment system
  • Removable cladding panels
  • Modular units extendable by 1172mm panels
  • Integral floor drainage
  • Acoustic and non-acoustic units
  • Delivery & installation normally carried out within 1 working day
  • The delivery will not have an effect on the critical path of the programme, as in-built plant has
  • The units can be fully tested, pre-commissioned & witnessed off site
  • Delivery time is normally 8-10 weeks from approval of drawings

Specification for EllisonAC Packaged Plant Roms

General

The container shall be manufactured by EllisonAC, provided with adequate means for lifting and positioning into final position utilising suitable cranage.

Construction

The container shall be a double skinned insulated one-piece unit constructed to be capable of accommodating the full operating load of the installed equipment / installations (both point loads and uniformly distributed loads).

Walls

External walls are to be constructed of steel panels, complete with adequate steel vertical supporting members at suitable centres. Heavy duty galvanised channel 41mm x 41mm x 2mm gap and 6mm return to be provided within each supporting member for pipework support and electrical containment systems as required.

External Finish

The steelwork frame to be generally painted with two coats air drying enamel to Colour Code BS.10A05 Goosewing Grey or equal.

Internal Finish

The steelwork frame to be as above. Silicone type sealant to be applied to panel joints where a weatherproof / air seal is required.

External/Internal Panels

Option A – Bonded Panels (also available as fire rated)

The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be 40mm thick zero ODP slab insulation.

Internally the panels will have bright white liner enamel affixed, encasing the whole panel.

Option B – Acoustic Panels (also available as fire rated)

The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be 80mm thick rockwool insulation.

Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation.

Option C – Bonded/Acoustic Panels (also available as fire rated)

The walls shall be preformed removable panels manufactured from Plastisol coated steel sheeting, and shall be an 80mm thick combination panel of 40mm thick zero ODP slab insulation and 40mm thick rockwool insulation.

Internally the panels will have a galvanised perforated sheet fixed with a glass fibre tissue membrane to prevent migration of the insulation.

All of the above cladding panels shall be affixed to the container from the outside thus allowing them to be removable should they be damaged or for plant replacement. Patent No. 2280206. All joints should have cover strips fitted, manufactured from the same materials as the external finish thus ensuring the unit has a homogeneous finish.

Roof

The roof shall be pitched from the central ridge, and shall be double skin, of steel construction, insulated to maintain minimum thermal transmittance. Roof finish to be same as walls (option A, B or C). Eaves to overhang walls. Guttering and downpipes shall be concealed type, manufactured from plastisol in the same colour as the unit.

Sub-Floor

Generally for container up to a gross weight of 20 tonnes the sub-floor and floor shall be as follows. All steel shall receive a coat of weldable primer. Shall be channel with the U-section of the channel facing all internal elevations. At 1M centres through the length of the container channel shall be fitted and run from side to side. All channels shall be fully weld prepped and receive 2 welds to all joints and butt joints. Running from end to end of the container shall be 2 sections of 100 x 100 angle which shall be weld prepped and fully welded.

Floor

On the floor shall be laid 4.5mm thick durbar plate and shall have no more than 4 joints throughout the total floor area. The durbar plate shall be welded to the sub-floor by stitch welding and there shall be a minimum of 20% of the steel contact area of the floor to the sub-base welded. All joints within the floor area shall be fully welded and prior to welding have been levelled from beneath to prevent ponding of water. A 200 x 4.5mm durbar kicker plate shall be welded to the completed floor to prevent damage to the container side panels. After the welding of the kicker plate the container shall be tested for leakage.

The completed floor shall receive 2-No. coats of epoxy non-slip semi matt floor paint to an approved colour. 1-No. coat shall be applied after completing all site works or commissioning. The sub-floor shall receive 2-No. coats of black bituminous paint applied by airless spray to ensure even coat to all steelwork.

Underfloor Insulation

To all the sub-floor area foil faced insulation board shall be affixed thus ensuring no underfloor condensation will form resulting in corrosion to the underfloor steelwork taking place.

Where entry point is requested through the floor, a 200mm high upstand detail can be provided, matching the general 200mm high skirting throughout the container.

Internal Drainage

Drainage will take place through the door thresholds out onto the roof area, or through an alternatively specified drain gully.

Doors

Outwards opening steel doors are to be provided as requested and hung on stainless steel security pattern hinges. Suitably designed internal door stays are also to be fitted and door clips to hold the doors back fully, if required. The minimum door opening is to be 1M wide x 2M high and is to be sized to facilitate removal of major plant/equipment items.

All doors to be constructed and insulated to the same thermal transmittance value as the container walls. A security lock is to be fitted.

Internal Plinths/Bases

Suitably designed pump plinths / bases can be provided where required, to comply with the requirements of equipment manufacturers.

Where bases are provided, they shall make all necessary provision to isolate vibration / noise transmission as required.

Technical information associated with: Ellison - Packaged Plant, Mobile Boiler Hire, Containerised Plantroom Solutions

 

Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms

Email this company

EllisonAC Limited
Woodgate Business Centre
White Lund Industrial Estate Morecambe
Lancashire
LA3 3PS

Tel: +44 (0) 1524 847470
Fax: +44 (0) 1524 845992

 

        Request further information:- please provide contact details: For UK and Europe only.
        * Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

        Please provide the project name and/or a short description of your requirements
       *Your Requirements

Validation :
Please type the number shown at the right



Request information above Technical information associated with EllisonAC Benefits of Packaged Plant Rooms Specification of Packaged Plant Rooms

Fully Featured HVAC Services Advertisers

Viessmann - Condensing Boilers Heat Pumps

Raychem T2 - Underfloor Heating

Sanyo - VRF Air Conditioning Space Air - Daikin Air Con Sytems

Sanyo - Air Conditioners Gas Heat Pump

Ellisons-Packaged Plant Rooms

Carrier - Aquasmart

Ellisons - Packaged Mobile Plant

JS - Portable air conditioners

Weatherite - Packaged AC/AHU's 

Daikin - VRV/Split AC Systems

2 Cool Aircon Chillers Air Handling Units

Daikin - Air & Water Cooled Chillers

Colman Moducel - Grilles Diffusers Louvres AHU

Uniflair - Close Control AC

Honeywell - Pressure regulating valves

Dunham Bush Heating / Cooling Products

Advanced Air - Dampers  & Air Distribution

Hitachi - Comfort Cooling / VRF

Belimo - Actuators

Iceboys - Portable air conditioning

Systemair - Axial Fans

Mitsubishi - VRF Air Conditioning Gilberts - Grilles / Air Movement

Mitsubishi - VRF Air Conditioning

Colt - Water Source Heat Pumps

AET - Underfloor Air Conditioning

Fulton - Steam & Thermal Fluid Boilers

Eaton Williams - Steam Humidifiers

Spirax-Sarco - Steam Services

Actionair - Smoke Control / Fan Coils

Monodraught - Natural Vent / Daylighting

Danfoss - Inverter Drives / Controls

Siemens - Building Management

Trend Control Systems - BMS / Controls

Airedale - Air conditioning chillers

Roberts Gordon - Space Heating

Frenger - Radiant Panels

Toshiba VRF Air Conditioning

Frenger - Chilled Beams / Ceilings

Britannia - Kitchen Ventilation

PIPE2000 - Pre Insulated Pipes Underfloor Heating

 

| Building Design HomeRequest information | Discussion Help | Terms of Use | Links | News |
| Architectural CPD Seminar Index | HVAC CPD Seminar Index | Electrical CPD Seminar Index |
| Architectural Technical Pages index | Electrical Technical Pages index | Mechanical Technical index

| F1 | F2 | F3 | F4 | F5| A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products |

Useful building design and construction links -




Recruitment -
Architect Jobs Electrical Engineer Jobs Building Engineering Jobs AutoCad Operator Jobs Structural Engineer Jobs