At the heart of Daikin chiller Technology is a compressor. The Single Screw Compressor

Daikin high-capacity chillers comprise a semi-hermetic single stepless screw compressor meeting the most exacting requirements in terms of capacity (stepless control from 25% to 100% on a single compressor),
performance and maintenance.

Extremely reliable over long periods of operation, this system only requires inspection after 40,000 hours of use, which is equivalent to 4.5 years of continuous operation. It has been developed to operate with refrigerants R-134a and R-407C.

Single Stepless Screw Compressor

Characteristics:

  • Compact, simple yet robust construction
  • Extremely low step load, with axial & radical forces properly balanced thanks to symmetrical compression achieved using a single rotor & two vacuum rotating gates
  • Hard-wearing gates made of polymer material resulting in reduced frictions & thus greatly reduced wear reduced losses of power
  • No oil pump required – the compressor screw is chilled & sealed from the rest of the installation using oil injection & refrigerant, therefore providing a constant operating temperature throughout the system’s complete services life & reduced play of the rotor for more accurate & efficient compression
  • Ultra-low vibration level, thus resulting in reduced system wear & a low sound level during operation (integrated in-compressor silent operation)
  • Easy access to both compressor & safety devices
  • Star-delta starter with low start-up current as standard

A new generation of heat pumps, EWYD260-380(kW) has been designed with all of the best technology currently available: besides the single screw compressors, R134a refrigerant and Variable frequency drivers (inverters), also all of the other components are selected among the most efficient and hi-level available choices: like electronic expansion valve, high efficiency shell and tube evaporators etc.

The Swing Compressor

The Swing Compressor

Inverter technology is also used in the new mini chiller (EWA/YQ005-007(kW). The swing compressor is an innovative design by Daikin, with fewer moving parts allowing smoother and more reliable operation with low vibration and noise levels. The newly developed high efficiency motor further reduces energy consumption resulting in high energy cost savings.

The Scroll Compressor

The smaller Daikin chillers are designed around a Daikin scroll hermetic compressor. This compressor has been developed throughout its service life.

Characteristics:

  • Compact, simple yet robust
  • Absence of valves & oscillating connecting mechanisms providing maximum reliability
  • Constant compression guaranteeing low energy consumption
  • Increased compression efficiency thanks to the absence of volumetric re-expansion
  • Low sound level
  • Low starting current

DICN Chiller Network

DICN Chiller Network

With the DICN system, it is possible to control up to 4 chillers. Different chillers can be mixed through each other, as long as they stay within 1 of the 3 groups as mentioned below:

Watercooled chillers: EWWD120-540MBYNN, EWAQ080-260DAYNN & EWYQ080-250DAYNN

Aircooled chillers: EWAP110-540MBYNN, EWAD120-340MBYNN

Remote condenser water chillers - cooling only: EWLD120-540MBYNN

The D.I.C.N. option allows simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control.

It is also possible to define units as manual or automatic standby units which is useful for back up purposes guaranteeing reliable operation of the chiller plant.

The chillers, grouped in a D.I.C.N., can also be integrated in a Building Management system (B.M.S.), using the B.M.S. options. It is possible to reduce sound levels e.g. during night time, by limitation of the capacity
of the system.
For energy saving, it is possible to work with dual setpoints (e.g. a lower or higher setpoint during night time).

Standard Anti-Corrosion Treatment

As standard condensers for air cooled chillers are given anti-corrosion treatment. This treatment significantly increases resistance to acid rain and saline corrosion.

 

The Single Screw Compressor

Email this company

Daikin Airconditioning UK Ltd
The Heights
Brooklands
Weybridge
Surrey
KT13 0NY

Tel : 01932 879000
Fax : 01932 879009

Daikin high-capacity chillers

        Request further information:- please provide contact details: For UK and Europe only.
        * Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

        Please provide the project name and/or a short description of your requirements
       *Your Requirements

Validation :
Please type the number shown at the right



Request information above Technical information associated with Daikin Chiller Technology

Fully Featured HVAC Services Advertisers

Viessmann - Condensing Boilers Heat Pumps

Raychem T2 - Underfloor Heating

Sanyo - VRF Air Conditioning Space Air - Daikin Air Con Sytems

Sanyo - Air Conditioners Gas Heat Pump

Ellisons-Packaged Plant Rooms

Carrier - Aquasmart

Ellisons - Packaged Mobile Plant

JS - Portable air conditioners

Weatherite - Packaged AC/AHU's 

Daikin - VRV/Split AC Systems

2 Cool Aircon Chillers Air Handling Units

Daikin - Air & Water Cooled Chillers

Colman Moducel - Grilles Diffusers Louvres AHU

Uniflair - Close Control AC

Honeywell - Pressure regulating valves

Dunham Bush Heating / Cooling Products

Advanced Air - Dampers  & Air Distribution

Hitachi - Comfort Cooling / VRF

Belimo - Actuators

Iceboys - Portable air conditioning

Systemair - Axial Fans

Mitsubishi - VRF Air Conditioning Gilberts - Grilles / Air Movement

Mitsubishi - VRF Air Conditioning

Colt - Water Source Heat Pumps

AET - Underfloor Air Conditioning

Fulton - Steam & Thermal Fluid Boilers

Eaton Williams - Steam Humidifiers

Spirax-Sarco - Steam Services

Actionair - Smoke Control / Fan Coils

Monodraught - Natural Vent / Daylighting

Danfoss - Inverter Drives / Controls

Siemens - Building Management

Trend Control Systems - BMS / Controls

Airedale - Air conditioning chillers

Roberts Gordon - Space Heating

Frenger - Radiant Panels

Toshiba VRF Air Conditioning

Frenger - Chilled Beams / Ceilings

Britannia - Kitchen Ventilation

PIPE2000 - Pre Insulated Pipes Underfloor Heating

 

| Building Design HomeRequest information | Discussion Help | Terms of Use | Links | News |
| Architectural CPD Seminar Index | HVAC CPD Seminar Index | Electrical CPD Seminar Index |
| Architectural Technical Pages index | Electrical Technical Pages index | Mechanical Technical index

| F1 | F2 | F3 | F4 | F5| A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products |

Useful building design and construction links -
Abacus Construction Index - Recommended websites for the UK construction industry
Sapling.info - The Architecture, Planning and Landscape Information Gateway
Lighting Directory - Comprehensive lighting information


Recruitment -
Architect Jobs Electrical Engineer Jobs Building Engineering Jobs AutoCad Operator Jobs Structural Engineer Jobs