Water Heaters Condensing storage water heaters commercial heaters

Information from Andrews Water Heaters

Water Heaters Condensing storage water heaters commercial heaters
Water Heaters Condensing storage water heaters commercial heaters     

Water Heaters Condensing storage water heaters commercial heaters

Request Information on other Products

Contact Andrews

Request Quote or Pre-Tender information

Request CPD Seminar

Information from Andrews

 

Subscribe to Newsletter

Employers - Advertise Job or Position

Submit Candidates Curriculum Vitae

Building Design Home

Contact Building Design

Advertise your Company on Building Design

Terms of Use

Links

Information - Andrews

Information on other Products

Water Heating

Subscribe to Newsletter

Contact Andrews

Request CPD Seminar

 

Andrews Water Heaters
Condensing Storage Water Heaters & Commercial Heaters


Andrews’ Largest Solar Thermal Water Heating System for new Travelodge in Fulham

In Andrews Water Heaters’ largest SOLARflo water heating installation to date, the newly opened Travelodge in Fulham has been equipped with 33 solar panels, 3 single coil pre-heat tanks and 2 ECOflo water heaters which supply domestic hot water to the 74 rooms, each of which has an en suite bath or shower room. Developed by Lombard Asset Management (Bahamas) Limited, the four storey building accommodates ground floor retail accommodation with the Travelodge located on three floors above. Renewable energy was a requirement of planning consent which would not have been granted without a contribution of 37,000 kWh of energy produced from a solar DHW system. Since at least 85-90% of the hotel’s rooms have been occupied every night since it opened, an efficient, reliable and cost effective source of hot water was essential.

The solar panels are located on the roof, whilst the water heaters, cylinders and other solar equipment are housed in a mezzanine plant room above the retail store on the ground floor. Each of the 33 glazed flat plate collectors has an area of 2.55 square metres, giving a total collector area of 84.15 square metres.

These solar collectors provide 90.8% transmission efficiency, 95% absorption efficiency and a low emission loss of only 5%. Water is preheated by the solar collectors, which are positioned to optimise their solar gain and heat is transferred to the three 1250 litre single coil cylinders. These in turn supply preheated water to the two ECOflo 380/1400 water heaters, thereby considerably reducing consumption of natural gas. The high efficiency, gas-fired, condensing storage water heaters installed each have a capacity of 380 litres and a recovery rate through 50ºC of 1400 litres per hour.

The SOLARflo water heating package and ECOflo water heaters were installed by MITIE Engineering Limited who selected the SOLARflo and ECOflo equipment to meet both end user requirements and space availability in the plant room. In addition to the glazed flat plate solar collectors and non-corrosive, stainless steel solar cylinders the complete SOLARflo package also includes solar controls, pump station, expansion vessels, first fill of heat transfer fluid and collector mounting accessories. Matched equipment from a single source, together with the availability of technical advice throughout the installation, is a particular benefit of the Andrews Water Heaters’ product range and after sales service.

The ECOflo high efficiency water heaters feature a low NOx pre-mix power burner that is quiet in operation, and a gross efficiency up to 98%, keeping running costs to a minimum. The units incorporate Vitraglas® silica glass lined tanks which provides protection against the corrosive effect of hot water and guarantees a longer working life. Also standard are Correx maintenance free powered anodes, which substantially reduce service time and costs.

The factory fitted Hydrojet® sediment reduction system on the cold inlet connection helps to prevent sediment build-up at the base of the tank, giving a long working life. The option for these appliances to be flued either vertically or horizontally as room sealed balanced flue appliances greatly increases siting and installation flexibility. As with all Andrews water heaters, heat input and flow are carefully regulated to produce a closely controlled water temperature and a high temperature anti-legionella program, which is essential for hotel hot water installations, is incorporated as standard.

Travelodge was the first budget hotel brand to launch in the UK in 1985 and is now the fastest growing budget hotel chain in the country, operating 383 hotels, with over 27,000 rooms, in the UK, Ireland and Spain. In addition, over 20 new hotels are planned this year, including Travelodge Fulham which is now open for business. By the time of the 2012 Olympics, Travelodge aims to be the biggest hotel operator in London.

Andrews Water Heaters is part of Baxi Commercial Division which includes Potterton Commercial, suppliers of a wide range of gas, oil-fired and dual fuel commercial boilers featuring the latest heating technology for energy efficient operation. The breadth of commercial heating available from this single source is a benefit which is appreciated by both designers and installers due to readily available design advice and technical assistance during installation.
 

Request information:
Andrews Water Heaters boilers fan flue boilers oil fired boilers

Request information:
Baxi Technologies CHP combined heating and power mini-chp DACHS

Request information:
Potterton Commercial boilers packaged prefabricated boiler plant condensing boiler

Technical information associated with:
Baxi SenerTec Combined heat power chp domestic chp micro chp

Technical information associated with:
Potterton Commercial Boilers Commercial condensing boilers commercial boiler manufacturer


ondensing Storage Water Heaters

Solar Boilers - Hot Water Heating Solutions

Andrews Water Heaters
Wood Lane
Erdington
Birmingham
West Midlands
B24 9QP

Email this company

Tel: 0845 070 1056
Fax: 0845 070 1059

Andrews fan flue oil fired water heaters

 

 

Request further information:- please provide contact details: For UK and Europe only * Mandatory

*Full Name  
Title  
Enquiry Type    
*Organisation  
*Street Address  
Address (cont.)  
City  
County  
*Postal Code  
*Country  
*Phone  
FAX  
*Email  

 

 

*Please provide the project name and/or a short description of your requirements

Validation :
Please enter numbers shown



Request information: Andrews Water Heaters boilers fan flue boilers oil fired boilers

Fully Featured HVAC Technical Services Advertisers

Actionair Requirements for Fire Dampers Future Developments Dampers

AET Hiross Flexible Space Underfloor Air Conditioning technical information

Airedale energy efficiency ratio eurovent EER classification

Andrews Water Heaters Condensing storage water heaters commercial heaters

Aquilar refrigerant gas detection F-gas regulations BS EN378 BREEAM

Armacell Insulation Selector Insulation Product Selector

Armstrong pressurisation selection boosting selection

Armstrong suction guides and Flo-Trex valves

Armstrong sewage pump selection drainage pump selection

Baxi SenerTec Combined heat power chp domestic chp micro chp

Belimo pressure independent characterised valve overview technical information

Britannia Kitchen ventilation canopies technical information

Britannia Kitchen ventilation recirculation units technical information

Carlyle Environmental Heat Pump Design Principles & Sound Levels

Carrier Complete Air Conditioning System Solution

Certuss steam generator installation steam generation technical information

Colman Moducel energy saving data centre cooling cooling distribution

Colt International water source heat pump guidance

Coolmation Rhoss chillers & hybrid heat pumps technical information

Daikin Modular Heat Reclaim Units Information

Danfoss VLT Drives Principles Advantages of Inverter Drives

Dimplex air source heat pumps ground source heat pumps

Dunham-Bush Fan Coil Unit Acoustics Fan Coil Room Noise Levels

Eaton-Williams Group humidifier guide humidifier specification humidifier technical information

EllisonAC Benefits of Packaged Plant Rooms Specification

EllisonAC Details of Packaged Plant Rooms Specification

Emcel Filters typical filtration unit specifications filter technical information

Ener-G Ground Source Heat Pump GSHP Energy Management

Food Industry Technical Ltd Variable Ventilation Control Gas Isolation Proving

Flakt Woods Energy Saving Technology Technical Information

Frenger Radiant Heating radiant heaters radiant ceiling panel

Frenger Multiservice Chilled Beams passive chilled beams active chilled beams

Fulton Boiler Works steam boiler installation steam boilers

Gilberts Floor Swirl Diffusers GFS Series

Halton Foodservice Kitchen Ventilation Canopies

Halton Indoor Fire Safety Solutions Fire Damper Management Smoke Dampers

Hitachi Split Systems & Variable Refrigerant Flow

JS Air Curtains why an air curtain aircurtain technical information

JS Humidifiers humidifier technical specifications

Mitsubishi Electric Case Studies 1

Mitsubishi Electric Case Studies 2

Monodraught natural daylight systems natural lighting

Munters Technical Information associated wtih Dehumidification Systems

PIPE2000 Pipework specifications Pipework technical information

Pipe2000 Floor Heating Floor Cooling technical information

Potterton Commercial Boilers Commercial condensing boilers commercial boiler manufacturer

Quidos Energy Management Consultants Air Conditioning Inspection and Certification

Raychem Underfloor Heating Product Selection

Raychem Trace Heating Product Selector

Rycroft sizing of Rycroft HT Breeze Sizing Rycroft

Sanyo gas heat pumps technical background

Siemens Building Technologies Guidance for Control Valves in HVAC Applications

Space Air Conditioning Air Conditioning Solutions Information

Space Air Conditioning Heat Reclaim Heat Pump Systems

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 1

S&P Coil Products Heat Pumps & Heat Pipes Product Selection Part 2

Spirax Sarco steam pipe sizig condensate pipe sizing

Spirax Sarco steam tables steam data

Systemair Ltd Fan Engineering

Toshiba Split VRF Air Conditioning Systems Inverter Technology

Trend Control Sensor Installation Guide

Trend Psychrometric Chart

Trox Chilled Beams Technical Information Multi-service Chilled Beams

Trox Fan Coil Systems Technical Information VAV Fan

Uniflair close control AC data Uniflair chiller data

 

 

Building design directory Site Map
Page p1 p2 p3 p4 p5 p6 p7 p8 p9 p10 p11 p12 p13 p14 p15 p16 p17 p18 p19 p20 p21 p22 p23 p24

See also
Building Design News  |  Building Design Recruitment  |  Building Design Tenders

| Building Design Home | Request informationArchitectural CPD Seminars | HVAC CPD Seminars | Electrical CPD Seminars |
| Architectural Technical Pages Index | Electrical Technical Pages Index | Mechanical Technical Index | Discussion Help | News |

| F1 | F2 | F3 | F4 | F5 | A1 | A2 | A3 | A4 | A5 | Architectural Products | HVAC Products | Electrical Products | Terms of Use |

Catalogue Requests
| Architectural Request Index | Catalogue Request Index 1  | Catalogue Request Index 2Catalogue Request Index 3 |
| Catalogue Request Index 4 | Catalogue Request Index 5 | Catalogue Request Index 6 |

Useful building design and construction links - | Links Directory |





Recruitment
| Architect Jobs | Electrical Engineer Jobs | Building Engineering Jobs | AutoCad Operator Jobs | Structural Engineer Jobs | Links |

Arundel Jones Associates LLP | Tel : 01622 745333 | e-mail |