Naylor Lintels
Lintels l-strip steel
lintels concrete lintels.
Naylor, a manufacturer of building
materials since 1890, combines a wealth of experience in manufacturing techniques
and in-depth ranges with a reputation for quality products, service and value
for money. The Naylor lintel range has been continually improved and enhanced
over the last 30 years in response to ever changing customer requirements and
needs. The result is an unrivalled range offering lintels to suit every situation,
backed up by a speedy and efficient specials service. Lintels Product Range
Hi-Spec Range - The Naylor Hi-Spec lintel is the most widely
specified range of prestressed concrete lintels in the country. The system comprises
a range of high performance prestressed concrete units and stainless and galvanised
steel front trays. Fair Faced Range - A range of lintels with
the same high performance characteristics as the Hi-Spec range Fire-Spec
Range - Naylor Fire-Spec lintels are ex-steel mould finish high performance
units. They are available as standard with up to 2 hours fire resistance and as
specials with over 2 hours. Fair Face Fire-Spec Range - NaylorFair
Faced lintels are also available with a Fair Faced Class 'C'Fair Faced finish
with up to 2 hours fire resistance as standard. Colour-Spec Range -
A range of lintels colour washed to suit particular site requirements. The wash
acts as a stain, penetrating the concrete surface and equalizing colour variations.
It has a proven long life finish, reduces surface dusting and increases light
reflectivity. Colour-Spec lintels have the same high performance characteristics
as the Hi-Spec range. Chem-Spec Range - Lintels containing additives
for withstanding aggressive conditions such as for use in contaminated land. Typical
contaminates may include; sulphates, lead, petrochemicals, etc. Specials
Range - A speedy and efficient service offering solutions to difficult
site situations. Examples of specials produced include: large and unusual shaped
sections, lintels with inserts cast in and units with chamfers or notches. Ground
Beam Range - An application for which many of our Hi-Spec lintels are
suitable. Lintels may be built directly off pad foundations regardless of ground
conditions, saving time and money. Padstone Range - A comprehensive
range of dense concrete Padstones is also available. Non standard sections and
profiles are available upon request. L-Strip Range - L-Strip
is available in either stainless or galvanised steel and is also available with
a wider flange suitable for stonework outer leaf. It is designed for use independently
in traditional or timber framed construction. Economy Range
- A cost effective range of lintels for stockists, all fully reversible and available
in packs for ease of handling/ordering. All economy lintels are suitable for use
with L-Strip. Installation Concrete Lintels All
Hi-Spec, Fire-Spec and Fair Faced Naylor lintels are market 'TOP'. This surface
should remain uppermost at all times. It is important that lintels are installed
the correct way up. If the mark 'TOP' cannot readily be seen, the lintels should
be built-in in such a way that the reinforcing strand (visible on the end faces)
is in the bottom of the unit. Naylor Economy Lintels are fully reversible and
may be installed any way up. Lintels should be carefully bedded on a full
mortar joint. Wall ties should be positioned in accordance with current building
regulations. A damp proof course should be used for all lintels in external
walls, and must be fixed in accordance with building regulations. In cavity
construction, it is recommended that both internal and external leaves are taken
up uniformly. For spans in excess of 1200mm, it is good practice to provide temporary
support (at 1200mm centres). If lintels are supporting concrete floor load, a
minimum lintel depth of 140mm is recommended to allow for impact loads during
the actual placing of concrete flooring. L-Strip Steel Lintels A
thin mortar bed should be placed in the reveals of the external leaf and the L-Strip
bedded onto this. For spans in excess of 1200mm, temporary support (at 1200mm
centres) should be provided until the first few courses of masonry have matured:
window and door frames are normally sufficient for the particular purpose. Wall
ties should be positioned in accordance with current building regulations. Stacking
Timber bearers should be located near the ends of the lintels and placed vertically
in line. For those lintels marked 'TOP', it is important that these are stacked
the correct way up on firm ground. Cutting Concrete lintels may
be cut using a high speed disc cutter. Use of this should by a properly trained
operative taking due regard of current Health and Safety regulations. Quality
Standards The design of Naylor prestressed concrete lintels complies with
BS8110 part 1:1997: section 4. Naylor lintels are manufactured in accordance with
BS5977: part 2:1983. Materials used in the manufacture of Naylor prestressed
lintels comply with BS12 and BS882. The prestressing strand/wire complies with
BS5896. Naylor lintels have a low water absorption and as a result of the
quality controlled Hi-Spec dense concrete mix used in their manufacture, they
can therefore be used underground provided that the ends of the lintels have a
minimum 45mm cover of mortar to the ends of the reinforcing strands. L-Strip
lintels are manufactured from steel strip complying with BS EN 10025 with the
minimum yield stress of 175 N/mm2. Zinc coating is galvanised to BS2989Z2. L-Strip
is also produced in austenitic stainless steel conforming to grade 304:S15:BS1449:
part 2. Lengths Naylor lintels are available as standard in lengths
from 600mm to 3600mm. Longer and intermediate lengths are available on request.
Scope of Manufacture Limitations: Weight: max
4 tonne Width: max 2 metre Load Bearing Lintels are usually
supplied with the following allowances for bearing at each end: 100mm for
openings up to/including 1000mm 150mm for openings up to/including 3000mm
200mm for openings over 3000mm It is however, the responsibility of the
building designer to ensure that these are sufficient to avoid over-stressing
the masonry at the supports. Technical Services A free design and
technical service is available and advice is gladly given for particular requirements
and applications. Lintel schedules and calculations where required, can be provided
from working drawings. Naylor lintels can be specified from the NBS Plus Clauses
F30: 740 and F30: 750. | |