Carrier - CPD / Seminar Information

Click on the links below to request more information about a CPD:

Request Mechanical Information
CIBSE CPD Accreditation

All Carrier CPDs below conform with the following:

Duration: CPDs last on average 45 minutes unless stated otherwise

Accreditation: CIBSE

Carrier CPD Seminars last approximately 45 minutes and consist of the following:

Introduction / Course Presentation (see below for details) / Summary / Conclusions / Questions

Absorption Chillers and CHP - Mechanical

  • The history of absorption - an old idea comes of age
  • Fundamentals - how we use salt and water to generate cooling
  • Single Effect Theory - the operating cycle of the single effect unit
  • Capacity control - capacity control and part load
  • The purge system - the most important part of the unit
  • Crystallisation control - theory and practise
  • Performance characteristics - absorption units have their limits
  • Absorption and CHP - the basic system
  • Environmental considerations - can absorption enhance your green credentials?
  • System considerations - compromises are inevitable

Legislation, Energy Efficiency and Chiller Developments - Mechanical

Legislation

  • Energy performance of Buildings Directive
  • Renewables contribution
  • CHP and absorption; trigeneration
  • Compliance Guide

Energy Efficiency

  • Chiller full load efficiency
  • Part load and ‘off-design’ efficiency
  • System characteristics
  • ESEER and SEER
  • System modelling and system comparisons
  • System SEER calculation
  • Carrier product range

Chiller technology

  • 'Free' cooling systems
  • Heat pumps
  • Heat recovery
  • Turbocor compressor unit performance and drawbacks

Click on the link below to request more information about a CPD:

Request Mechanical Information

Downloadable Catalogues

Energy Efficiency & Legislation

For a system with multiple chillers for use in office buildings, combined EER values may be calculated based on the sum of the energy consumptions of...

Rooftop Packaged Systems

Carrier has over 100 years expertise in the manufacture of innovative, versatile, energy efficient Packaged Rooftop systems designed for longevity...

Low Energy Consumption

The LEC motor reduces fan coil consumption by 50% to 75%. The LEC option makes it easier to meet the new energy regulations in building energy...